But that drain line is pretty small so it doesn t take much for it to become clogged.
Hvac condensate drain line to sewer.
A clogged condensate drain line is one of the most common reasons homeowners need to call in for professional repair for their ac system.
Condensate switches imc 307 2 3 states that all hvac equipment that produces condensate must have either a secondary drain line or a condensate overflow switch a secondary drain pan with a secondary drain line or condensate switch or some combination of these installations should be used to prevent overflow if the primary drain line blocks.
Carson dunlop associates sketches left illustrate both acceptable and not recommended locations for the discharge of an air conditioner or heat pump condensate drain line discharge.
But you still need to confirm to yourself that the entire drain line has at least an eighth inch slope to it.
Uniform mechanical code section 310 0 310 1 condensate disposal.
Our photo left shows a white flexible tube used as condensate drain tubing for a split system air conditioning system being installed in a new york home.
Plumbing code citation for installation of air conditioning condensate drain piping.
Condensate drain leaks clogging.
Condensate drain to open sewer line.
This will kill any algae mold or mildew that has formed in the pipe.
When everything is working properly condensation runs down the drain line and exits outside your house.
Just pour a cup of bleach in the drain line s access opening near the indoor air conditioning unit.
Water lots of it.
That s the line that your air conditioner uses to get rid of all the humidity that it pulls from the air.
Because dry air holds less heat energy humidity.
Cleaning the line will remove clogs and blockages and prevent algae and mold from growing.
However many homeowners don t realize the problem is usually avoidable with regular care and diy ac maintenance.
If the condensate lines travel off the service platform and disappear in the insulation that s fine.
Even hvac technicians may forget to clean the drain during a regular service call which means that it s up to you to check and clean the condensate pan and drain line before a problem develops.
Air conditioning condensate waste pipes shall connect indirectly to the drainage system through an airgap or airbreak to a properly trapped and vented receptors dry wells leach pits or the tailpiece of plumbing fixtures.
Condensate waste shall not drain over a public way.
If your condensate drain line is clogged you can likely remove the clog yourself.
If the condensate drain line is clogged you will need to use a wet dry vacuum or a special pump to unclog the line.
Central air conditioners produce something other than cool comfort.